当前位置:首页 » 存储配置 » 什么是存储多路径

什么是存储多路径

发布时间: 2022-05-23 05:40:28

A. 华为2600t存储 多路径软件叫什么

只要存储网络中有多路径,不论是FC还是iSCSI,都需要多路径软件。当然可能存储厂家和服务器厂家都会有自己的多路径,那就只能选一个

B. linux 多路径存储是怎么回事

Linux下HDS存储多路径查看
在Redhat下确定需要划分的存储空间。在本例中需要进行划分的空间是从HDS AMS2000上划分到服务器的多路径存储空间。其中sddlmad为ycdb1上需要进行划分的空间,sddlmah为ycdb2上需要进行划分的空间。具体如下:
查看环境
# rpm -qa|grep device-mapper
device-mapper-event-1.02.32-1.el5
device-mapper-multipath-0.4.7-30.el5
device-mapper-1.02.32-1.el5
# rpm -qa|grep lvm2 lvm2-2.02.46-8.el5
查看空间
#fdisk -l
Disk /dev/sddlmad: 184.2 GB, 184236900352 bytes 255 heads, 63 sectors/track, 22398 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes
Disk /dev/sddlmah: 184.2 GB, 184236900352 bytes

255 heads, 63 sectors/track, 22398 cylinders Units = cylinders of 16065 * 512 = 8225280 bytes
查看存储
#cd /opt/DynamicLinkManager/bin/
#./dlnkmgr view -lu
Proct : AMS
SerialNumber : 83041424 LUs : 8
iLU HDevName Device PathID Status
0000 sddlmaa /dev/sdb 000000 Online
/dev/sdj 000008 Online
/dev/sdr 000016 Online
/dev/sdz 000017 Online

0001 sddlmab /dev/sdc 000001 Online
/dev/sdk 000009 Online
/dev/sds 000018 Online
/dev/sdaa 000019 Online
0002 sddlmac /dev/sdd 000002 Online
/dev/sdl 000010 Online
/dev/sdt 000020 Online
/dev/sdab 000021 Online
0003 sddlmad /dev/sde 000003 Online
/dev/sdm 000011 Online
/dev/s 000022 Online
/dev/sdac 000023 Online
0004 sddlmae /dev/sdf 000004 Online
/dev/sdn 000012 Online
/dev/sdv 000024 Online
/dev/sdad 000025 Online
0005 sddlmaf /dev/sdg 000005 Online
/dev/sdo 000013 Online
/dev/sdw 000026 Online
/dev/sdae 000027 Online
0006 sddlmag /dev/sdh 000006 Online
/dev/sdp 000014 Online
/dev/sdx 000028 Online
/dev/sdaf 000029 Online
0007 sddlmah /dev/sdi 000007 Online
/dev/sdq 000015 Online
/dev/sdy 000030 Online
/dev/sdag 000031 Online
##############################################################
4. lvm.conf的修改
为了能够正确的使用LVM,需要修改其过滤器:
#cd /etc/lvm #vi lvm.conf
# By default we accept every block device
# filter = [ "a/.*/" ]
filter = [ "a|sddlm[a-p][a-p]|.*|","r|dev/sd|" ]
例:

[root@bsrunbak etc]# ls -l lvm*

[root@bsrunbak etc]# cd lvm
[root@bsrunbak lvm]# ls
archive backup cache lvm.conf
[root@bsrunbak lvm]# more lvm.conf

[root@bsrunbak lvm]# pvs

Last login: Fri Jul 10 11:17:21 2015 from 172.17.99.198
[root@bsrunserver1 ~]#
[root@bsrunserver1 ~]#
[root@bsrunserver1 ~]# df -h
Filesystem Size Used Avail Use% Mounted on
/dev/sda4 30G 8.8G 20G 32% /
tmpfs 95G 606M 94G 1% /dev/shm
/dev/sda2 194M 33M 151M 18% /boot
/dev/sda1 200M 260K 200M 1% /boot/efi
/dev/mapper/datavg-oraclelv
50G 31G 17G 65% /oracle
172.16.110.25:/Tbackup
690G 553G 102G 85% /Tbackup
/dev/mapper/tmpvg-oradatalv
345G 254G 74G 78% /oradata
/dev/mapper/datavg-lvodc
5.0G 665M 4.1G 14% /odc
[root@bsrunserver1 ~]# pvs
PV VG Fmt Attr PSize PFree
/dev/sda5 datavg lvm2 a-- 208.06g 153.06g
/dev/sddlmba tmpvg lvm2 a-- 200.00g 49.99g
/dev/sddlmbb tmpvg lvm2 a-- 200.00g 0
[root@bsrunserver1 ~]# cd /etc/lvm
[root@bsrunserver1 lvm]# more lvm.conf
# Don't have more than one filter line active at once: only one gets
used.

# Run vgscan after you change this parameter to ensure that
# the cache file gets regenerated (see below).
# If it doesn't do what you expect, check the output of 'vgscan -vvvv'.

# By default we accept every block device:
# filter = [ "a/.*/" ]

# Exclude the cdrom drive
# filter = [ "r|/dev/cdrom|" ]

# When testing I like to work with just loopback devices:
# filter = [ "a/loop/", "r/.*/" ]

# Or maybe all loops and ide drives except hdc:
# filter =[ "a|loop|", "r|/dev/hdc|", "a|/dev/ide|", "r|.*|" ]

# Use anchors if you want to be really specific
# filter = [ "a|^/dev/hda8$|", "r/.*/" ]
filter = [ "a|/dev/sddlm.*|", "a|^/dev/sda5$|", "r|.*|" ]

[root@bsrunserver1 lvm]# df
Filesystem 1K-blocks Used Available Use% Mounted on
/dev/sda4 30963708 9178396 20212448 32% /
tmpfs 99105596 620228 98485368 1% /dev/shm
/dev/sda2 198337 33546 154551 18% /boot
/dev/sda1 204580 260 204320 1% /boot/efi
/dev/mapper/datavg-oraclelv
51606140 31486984 17497716 65% /oracle
172.16.110.25:/Tbackup
722486368 579049760 106736448 85% /Tbackup
/dev/mapper/tmpvg-oradatalv
361243236 266027580 76865576 78% /oradata
/dev/mapper/datavg-lvodc
5160576 680684 4217748 14% /odc
[root@bsrunserver1 lvm]#
You have new mail in /var/spool/mail/root
[root@bsrunserver1 lvm]#
[root@bsrunserver1 lvm]# pvs
PV VG Fmt Attr PSize PFree
/dev/sda5 datavg lvm2 a-- 208.06g 153.06g
/dev/sddlmba tmpvg lvm2 a-- 200.00g 49.99g
/dev/sddlmbb tmpvg lvm2 a-- 200.00g 0
[root@bsrunserver1 lvm]#
进入文件:
[root@bsrunbak lvm]# cd /opt/D*/bin
or
[root@bsrunbak bin]# pwd
/opt/DynamicLinkManager/bin
显示HDS存储卷:
[root@bsrunbak lvm]# ./dlnkmgr view -lu

C. 如何实施SAN多路径以及重要的考虑因素(含视频)

因此,如果两者之间只有一条路径的话,那么很可能会出现问题。SAN多路径技术通过在硬件之间建立多条路径的方式可以解决这个问题,一条路径发生故障后,I/O可以使用另一条。多路径还可以实现负载均衡。在下面的视频中,存储专家Howard Marks探讨了实施SAN多路径的一些实践。任何接触过存储区域网络(SAN)的人都遇到过路径失效的问题。人们常常会拔掉电缆或者关闭电源。这时服务器和存储设备都运行良好,但它们之间却没有有效的路径可用。所以,有必要建立一种机制来支持多路径。微软和VMware都已经在它们的核心产品中建立了原始的多路径,并嵌入了由存储阵列厂商或第三方组织提供的插件,这样使得多路径技术更高效。VMware的多路径方式是失效备援。如果你的主机上有一个双端口光纤通道(FC)适配器,把它们连接到两个独立的开关上,也就是你的磁盘阵列同时连接了两个开关,这时所有的流量都使用其中一条路径,除非这条路径失效。你也可以将开关转到循环档,这时会有交替的请求通过这些路径,但是由于这些请求不会按照你想象的那样只在一条路径上传输,所以这种循环路径不会产生双倍的带宽。有效带宽只能达到1.6倍。

D. 修改主机存储多路径属于下面哪个功能配置

Linux多路径指的是除了主机和硬盘一条路径的连接,还包括了主机和网络服务器的连接形成的主机一对多的路径连接关系。通过多路径的连接,实现了磁盘的虚拟化。
1、安装多路径软件包:
device-mapper-1.02.67-2.el5
device-mapper-event-1.02.67.2.el5
device-mapper-multipath-0.4.7-48.el5
[root@RKDB01 Server]# rpm -ivh device-mapper-1.02.67-2.el5.x86_64.rpm
warning: device-mapper-1.02.67-2.el5.x86_64.rpm: Header V3 DSA signature: NOKEY, key ID 37017186
Preparing.…… ########################################### [100%]
package device-mapper-1.02.67-2.el5.x86_64 is already installed
[root@RKDB01 Server]# rpm -ivh device-mapper-event-1.02.67-2.el5.x86_64.rpm
warning: device-mapper-event-1.02.67-2.el5.x86_64.rpm: Header V3 DSA signature: NOKEY, key ID 37017186
Preparing.…… ########################################### [100%]
package device-mapper-event-1.02.67-2.el5.x86_64 is already installed
[root@RKDB01 Server]# rpm -ivh device-mapper-multipath-0.4.7-48.el5.x86_64.rpm
warning: device-mapper-multipath-0.4.7-48.el5.x86_64.rpm: Header V3 DSA signature: NOKEY, key ID 37017186
Preparing.…… ########################################### [100%]
package device-mapper-multipath-0.4.7-48.el5.x86_64 is already installed
2、设置开机启动,并检查安装包是否正常:
chkconfig --level 345 multipathd on
lsmod |grep dm_multipath
[root@RKDB01 Server]# chkconfig --level 345 multipathd on
[root@RKDB01 Server]# lsmod |grep dm_multipath
dm_multipath 58969 0
scsi_dh 42561 1 dm_multipath
dm_mod 102417 4 dm_mirror,dm_multipath,dm_raid45,dm_log
[root@RKDB01 Server]#
3、配置multipathd 使其正常工作,编辑/etc/multipath.conf,开放如下内容:
defaults {
udev_dir /dev
polling_interval 10
selector “round-robin 0”
path_grouping_policy multibus
getuid_callout “/sbin/scsi_id -g -u -s /block/%n”
prio_callout none
path_checker readsector0
rr_min_io 100
max_fds 8192
rr_weight priorities
failback immediate
no_path_retry fail
user_friendly_names yes
}
blacklist {
wwid 26353900f02796769
devnode “^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*”
devnode “^hd[a-z]”
}
4、并关闭如下内容
#blacklist {
# devnode “*”
#}
#defaults {
27 # user_friendly_names yes
28 #}
5、完成之后执行如下命令发现多路径:
[root@RKDB01 Server]# modprobe dm-multipath
[root@RKDB01 Server]# multipath -F
[root@RKDB01 Server]# multipath dm-multipath
[root@RKDB01 Server]# multipath dm-round-robin
[root@RKDB01 Server]# service multipathd restart
正在关闭multipathd 端口监控程序: [确定]
正在启动守护进程multipathd: [确定]
[root@RKDB01 Server]# multipath -v2
[root@RKDB01 Server]# multipath -v2
[root@RKDB01 Server]# multipath -ll
mpath1 () dm-0 TOYOU,NetStor_iSUM510
[size=3.3T][features=0][hwhandler=0][rw]
\_ round-robin 0 [prio=2][ena bled]
\_ 1:0:0:0 sdb 8:16 [failed][ready]
\_ 1:0:1:0 sdc 8:32 [failed][ready]
[root@RKDB01 Server]#
6、重启服务器后,可以看到多路径信息了:
[root@RKDB01 ~]# ll /dev/mapper/
总计 0
crw------- 1 root root 10, 60 11-05 22:35 control
brw-rw---- 1 root disk 253, 0 11-05 22:35 mpath1
brw-rw---- 1 root disk 253, 1 11-05 22:35 mpath2
[root@RKDB01 ~]# multipath -ll
mpath2 () dm-1 TOYOU,NetStor_iSUM510
[size=3.2T][features=0][hwhandler=0][rw]
\_ round-robin 0 [prio=2][active]
\_ 1:0:0:1 sdc 8:32 [active][ready]
\_ 1:0:1:1 sde 8:64 [active][ready]
mpath1 () dm-0 TOYOU,NetStor_iSUM510
[size=20G][features=0][hwhandler=0][rw]
\_ round-robin 0 [prio=2][active]
\_ 1:0:0:0 sdb 8:16 [active][ready]
\_ 1:0:1:0 sdd 8:48 [active][ready]
7、通过fdisk 看可以生成了DM-0/DM-1两个盘,正是上面sdc/sde,sdb/sdd多路径后出来的:
[root@RKDB01 ~]# fdisk -l
Disk /dev/sda: 299.4 GB, 299439751168 bytes
255 heads, 63 sectors/track, 36404 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Device Boot Start End Blocks Id System
/dev/sda1 * 1 38 305203+ 83 Linux
/dev/sda2 39 13092 104856255 83 Linux
/dev/sda3 13093 19619 52428127+ 83 Linux
/dev/sda4 19620 36404 134825512+ 5 Extended
/dev/sda5 19620 26146 52428096 83 Linux
/dev/sda6 26147 28757 20972826 83 Linux
/dev/sda7 28758 30324 12586896 82 Linux swap / Solaris
/dev/sda8 30325 36404 48837568+ 83 Linux
Disk /dev/sdb: 21.4 GB, 21474836480 bytes
255 heads, 63 sectors/track, 2610 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Disk /dev/sdb doesn't contain a valid partition table
Disk /dev/sdc: 3568.4 GB, 3568429957120 bytes
255 heads, 63 sectors/track, 433836 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Disk /dev/sdc doesn't contain a valid partition table
Disk /dev/sdd: 21.4 GB, 21474836480 bytes
255 heads, 63 sectors/track, 2610 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Disk /dev/sdd doesn't contain a valid partition table
Disk /dev/sde: 3568.4 GB, 3568429957120 bytes
255 heads, 63 sectors/track, 433836 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Disk /dev/sde doesn't contain a valid partition table
Disk /dev/dm-0: 21.4 GB, 21474836480 bytes
255 heads, 63 sectors/track, 2610 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Disk /dev/dm-0 doesn't contain a valid partition table
Disk /dev/dm-1: 3568.4 GB, 3568429957120 bytes
255 heads, 63 sectors/track, 433836 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Disk /dev/dm-1 doesn't contain a valid partition table
Disk /dev/sdf: 4009 MB, 4009754624 bytes
255 heads, 63 sectors/track, 487 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Device Boot Start End Blocks Id System
/dev/sdf4 * 1 488 3915744+ b W95 FAT32
Partition 4 has different physical/logical endings:
phys=(486, 254, 63) logical=(487, 125, 22)
[root@RKDB01 ~]#
8、同时也可以在/dev/mapper目录中查看到多路径映射的信息:
[root@RKDB01 ~]# ll /dev/mapper/
总计 0
crw------- 1 root root 10, 60 11-06 00:49 control
brw-rw---- 1 root disk 253, 2 11-06 00:49 data-data001
brw-rw---- 1 root disk 253, 0 11-06 00:49 mpath1
brw-rw---- 1 root disk 253, 1 11-06 00:49 mpath2

E. AIX连接IBM存储,多路径软件常用命令

AIX连接IBM存储,多路径软件常用命令一:查看存储盘的路径1、
查看MPIO的存储盘的路径#
lspath
(适用于所有存储的MPIO路径查询)#
mpio_get_config
-Av
(适用于DS3K/DS4K的MPIO路径查询)2、
查看RDAC存储盘的路径#
fget_config
-Av
(适用于DS3K/DS4K的RDAC路径查询)3、
查看SDDPCM存储盘的路径#
pcmpath
query
device
(适用于DS6K/DS8K和v7000的SDDPCM路径查询)#pcmpath
query
adapter
检查
SDDPCM
适配器状态#pcmpath
query
wwpn
检查
SDDPCM
已知的
FC
适配器
WWPN#pcmpath
query
version
检查
SDDPCM
级别#lspath
检查是否启用了所有磁盘路径4、
查看当前操作系统自带的支持IBM存储的多路径软件#
manage_disk_drivers5、
将DS4700默认的多路径软件更改成RDAC#
manage_disk_drivers
-d
DS4700
-o
AIX_fcparray

F. 存储多路径是个什么意思

机身储存是电子数码产品或设备(如手机、MP3、电脑等)本身所带的内部存储介质,由存储芯片直接安装在仪器或是设备内部,以支撑机器的正常运行,用于暂时存放运算数据,以及与外部存储器交换的数据。目前主流的机身储存容量有8GB、16GB、和32GB。运行内存是指手机运行程序时的内存,也叫RAM(简称运存)。用电脑比较的话手机的运行内存就是电脑的内存,是不可以作为储存数据的介质的。目前智能手机运行内存一般为1GB、2GB或3GB。

G. 如何使用Linux自带多路径DM

一、多路径解释
多路径,顾名思义就是有多种选择的路径。在SAN或IPSAN环境,主机和存储之间外加了光纤交换机,这就导致主机和存储之间交换速度和效率增强,一条路径肯定是不行的,也是不安全不稳定的。多路径就是要来解决从主机到磁盘之间最快,最高效的问题。主要实现如下几个功能
故障的切换和恢复
IO流量的负载均衡
磁盘的虚拟化
多路径之前一直是存储厂商负责解决,竟来被拆分出来单独卖钱了。
构架基本是这样的:存储,多路径软件,光纤交换机,主机,主机系统。

二、LINUX下的multipath
1、查看是否自带安装?

1
2
3
4
5
6

[root@web2 multipath]# rpm -qa|grep device
device-mapper-1.02.39-1.el5
device-mapper-1.02.39-1.el5
device-mapper-multipath-0.4.7-34.el5
device-mapper-event-1.02.39-1.el5
[root@web2 multipath]#

2、安装

1
2
3
4
5
6

rpm -ivh device-mapper-1.02.39-1.el5.rpm #安装映射包
rpm -ivh device-mapper-multipath-0.4.7-34.el5.rpm #安装多路径包

外加加入开机启动
chkconfig –level 2345 multipathd on #设置成开机自启动multipathd
lsmod |grep dm_multipath #来检查安装是否正常

3、配置

1
2
3
4
5
6
7
8
9
10
11
12
13
14

# on the default devices.
blacklist {
devnode "^(ram|raw|loop|fd|md|dm-|sr|sr|scd|st)[0-9]*"
devnode "^hd[a-z]"
}
devices {
device {
vendor "HP"
path_grouping_policy multibus
features "1 queue_if_no_path"
path_checker readsector()
failback immediate
}
}<br><br>完整的配置如下:

blacklist {
devnode "^sda"
}

defaults {
user_friendly_names no
}

multipaths {
multipath {
wwid
alias iscsi-dm0
path_grouping_policy multibus
path_checker tur
path_selector "round-robin 0"
}
multipath {
wwid
alias iscsi-dm1
path_grouping_policy multibus
path_checker tur
path_selector "round-robin 0"
}
multipath {
wwid
alias iscsi-dm2
path_grouping_policy multibus
path_checker tur
path_selector "round-robin 0"
}
multipath {
wwid
alias iscsi-dm3
path_grouping_policy multibus
path_checker tur
path_selector "round-robin 0"
}
}

devices {
device {
vendor "iSCSI-Enterprise"
proct "Virtual disk"
path_grouping_policy multibus
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
path_checker readsector0
path_selector "round-robin 0"
}
}
4、命令

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

[root@web2 ~]# multipath -h
multipath-tools v0.4.7 (03/12, 2006)
Usage: multipath [-v level] [-d] [-h|-l|-ll|-f|-F|-r]
[-p failover|multibus|group_by_serial|group_by_prio]
[device]

-v level verbosity level
0 no output
1 print created devmap names only
2 default verbosity
3 print debug information
-h print this usage text
-b file bindings file location
-d dry run, do not create or update devmaps
-l show multipath topology (sysfs and DM info)
-ll show multipath topology (maximum info)
-f flush a multipath device map
-F flush all multipath device maps
-r force devmap reload
-p policy force all maps to specified policy :
failover 1 path per priority group
multibus all paths in 1 priority group
group_by_serial 1 priority group per serial
group_by_prio 1 priority group per priority lvl
group_by_node_name 1 priority group per target node

device limit scope to the device's multipath
(udev-style $DEVNAME reference, eg /dev/sdb
or major:minor or a device map name)
[root@web2 ~]#

5、启动关闭

1
2
3
4

# /etc/init.d/multipathd start #开启mulitipath服务
service multipath start
service multipath restart
service multipath shutdown

6、如何获取wwid

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

1、
[root@vxfs01 ~]# cat /var/lib/multipath/bindings
# Multipath bindings, Version : 1.0
# NOTE: this file is automatically maintained by the multipath program.
# You should not need to edit this file in normal circumstances.
#
# Format:
# alias wwid
#
mpath0
mpath1
mpath2
mpath3
mpath4

2、
[root@vxfs01 ~]# multipath -v3 |grep 3600
sdb: uid = (callout)
sdc: uid = (callout)
sdd: uid = (callout)
sde: uid = (callout)
1:0:0:0 sdb 8:16 0 [undef][ready] DGC,RAI
1:0:1:0 sdc 8:32 1 [undef][ready] DGC,RAI
2:0:0:0 sdd 8:48 1 [undef][ready] DGC,RAI
2:0:1:0 sde 8:64 0 [undef][ready] DGC,RAI
Found matching wwid [] in bindings file.

比较详细的文字:
http://zhumeng8337797.blog.163.com/blog/static/1007689142013416111534352/
http://blog.csdn.net/wuweilong/article/details/14184097
RHEL官网资料:
http://www.prudentwoo.com/wp-content/uploads/downloads/2013/11/Red_Hat_Enterprise_Linux-5-DM_Multipath-en-US.pdf
http://www.prudentwoo.com/wp-content/uploads/downloads/2013/11/Red_Hat_Enterprise_Linux-5-DM_Multipath-zh-CN.pdf
http://www.prudentwoo.com/wp-content/uploads/downloads/2013/11/Red_Hat_Enterprise_Linux-6-DM_Multipath-en-US.pdf
http://www.prudentwoo.com/wp-content/uploads/downloads/2013/11/Red_Hat_Enterprise_Linux-6-DM_Multipath-zh-CN.pdf

H. esxi6.0怎么设置存储多链路

应该说是优化吧,
底层物理 确认有多条链路之后,格式化存储完成之后,在存储器里右键编辑存储的名称属性,点 管理冗余链路,上面有个多路径 默认是固定,把他设置成循环就行了

I. 什么是多路径I/O

多路径I/O指主机中能够将对存储设备的I/O请求定向到多条访问路径上的设施和机制,它要求必须使用除总线地址之外的方法来惟一标识设备。

J. emc存储multipath问题求助

LINUX下多路径(multi-path)介绍及使用

一、什么是多路径
普通的电脑主机都是一个硬盘挂接到一个总线上,这里是一对一的关系。而到了有光纤组成的SAN环境,或者由iSCSI组成的IPSAN环境,由于主机和存储通过了光纤交换机或者多块网卡及IP来连接,这样的话,就构成了多对多的关系。也就是说,主机到存储可以有多条路径可以选择。主机到存储之间的IO由多条路径可以选择。每个主机到所对应的存储可以经过几条不同的路径,如果是同时使用的话,I/O流量如何分配?其中一条路径坏掉了,如何处理?还有在操作系统的角度来看,每条路径,操作系统会认为是一个实际存在的物理盘,但实际上只是通向同一个物理盘的不同路径而已,这样是在使用的时候,就给用户带来了困惑。多路径软件就是为了解决上面的问题应运而生的。
多路径的主要功能就是和存储设备一起配合实现如下功能:
1.故障的切换和恢复
2.IO流量的负载均衡
3.磁盘的虚拟化
由于多路径软件是需要和存储在一起配合使用的,不同的厂商基于不同的操作系统,都提供了不同的版本。并且有的厂商,软件和硬件也不是一起卖的,如果要使用多路径软件的话,可能还需要向厂商购买license才行。比如EMC公司基于linux下的多路径软件,就需要单独的购买license。好在, RedHat和Suse的2.6的内核中都自带了免费的多路径软件包,并且可以免费使用,同时也是一个比较通用的包,可以支持大多数存储厂商的设备,即使是一些不是出名的厂商,通过对配置文件进行稍作修改,也是可以支持并运行的很好的。


二、Linux下multipath介绍,需要以下工具包:
在CentOS 5中,最小安装系统时multipath已经被安装,查看multipath是否安装如下:


1、device-mapper-multipath:即multipath-tools。主要提供multipathd和multipath等工具和 multipath.conf等配置文件。这些工具通过device mapper的ioctr的接口创建和配置multipath设备(调用device-mapper的用户空间库。创建的多路径设备会在/dev /mapper中)。

2、 device-mapper:主要包括两大部分:内核部分和用户部分。内核部分主要由device mapper核心(dm.ko)和一些target driver(md-multipath.ko)。核心完成设备的映射,而target根据映射关系和自身特点具体处理从mappered device 下来的i/o。同时,在核心部分,提供了一个接口,用户通过ioctr可和内核部分通信,以指导内核驱动的行为,比如如何创建mappered device,这些divece的属性等。linux device mapper的用户空间部分主要包括device-mapper这个包。其中包括dmsetup工具和一些帮助创建和配置mappered device的库。这些库主要抽象,封装了与ioctr通信的接口,以便方便创建和配置mappered device。multipath-tool的程序中就需要调用这些库。
3、dm-multipath.ko和dm.ko:dm.ko是device mapper驱动。它是实现multipath的基础。dm-multipath其实是dm的一个target驱动。
4、scsi_id: 包含在udev程序包中,可以在multipath.conf中配置该程序来获取scsi设备的序号。通过序号,便可以判断多个路径对应了同一设备。这个是多路径实现的关键。scsi_id是通过sg驱动,向设备发送EVPD page80或page83 的inquery命令来查询scsi设备的标识。但一些设备并不支持EVPD 的inquery命令,所以他们无法被用来生成multipath设备。但可以改写scsi_id,为不能提供scsi设备标识的设备虚拟一个标识符,并输出到标准输出。multipath程序在创建multipath设备时,会调用scsi_id,从其标准输出中获得该设备的scsi id。在改写时,需要修改scsi_id程序的返回值为0。因为在multipath程序中,会检查该直来确定scsi id是否已经成功得到。
三、multipath在CentOS 5中的基本配置过程:
1、安装和加载多路径软件包
# yum –y install device-mapper device-mapper-multipath
# chkconfig –level 2345 multipathd on #设置成开机自启动multipathd
# lsmod |grep dm_multipath #来检查安装是否正常


如果模块没有加载成功请使用下列命初始化DM,或重启系统
---Use the following commands to initialize and start DM for the first time:
# modprobe dm-multipath
# modprobe dm-round-robin
# service multipathd start
# multipath –v2

2、配置multipath:
Multipath的配置文件是/etc/multipath.conf , 如需要multipath正常工作只需要如下配置即可:(如果需要更加详细的配置,请看本文后续的介绍)
blacklist {
devnode "^sda"
}
defaults {
user_friendly_names yes
path_grouping_policy multibus
failback immediate
no_path_retry fail
}
# vi /etc/multipath.conf3、multipath基本操作命令
# /etc/init.d/multipathd start #开启mulitipath服务
# multipath -F #删除现有路径
# multipath -v2 #格式化路径
# multipath -ll #查看多路径


如果配置正确的话就会在/dev/mapper/目录下多出mpath0、mpath1等之类设备。


用fdisk -l命令可以看到多路径软件创建的磁盘,如下图中的/dev/dm-[0-3]4、multipath磁盘的基本操作
要对多路径软件生成的磁盘进行操作直接操作/dev/mapper/目录下的磁盘就行.
在对多路径软件生成的磁盘进行分区之前最好运行一下pvcreate命令:
# pvcreate /dev/mapper/mpath0
# fdisk /dev/mapper/mpath0


用fdisk对多路径软件生成的磁盘进行分区保存时会有一个报错,此报错不用理会。
fdisk对多路径软件生成的磁盘进行分区之后,所生成的磁盘分区并没有马上添加到/dev/目录下,此时我们要重启IPSAN或者FCSAN的驱动,如果是用iscsi-initiator来连接IPSAN的重启ISCSI服务就可以发现所生成的磁盘分区了
# service iscsi restart
# ls -l /dev/mapper/


如上图中的mpath0p1和mpath1p1就是我们对multipath磁盘进行的分区
# mkfs.ext3 /dev/mapper/mpath0p1 #对mpath1p1分区格式化成ext3文件系统
# mount /dev/mapper/mpath0p1 /ipsan/ #挂载mpath1p1分区

热点内容
3k我的使命脚本 发布:2024-09-20 18:11:43 浏览:689
建设银行密码怎么设置 发布:2024-09-20 18:11:04 浏览:95
聚合脚本平台 发布:2024-09-20 17:51:55 浏览:180
访问拦截怎么解除安卓 发布:2024-09-20 17:28:48 浏览:275
萝卜干存储 发布:2024-09-20 17:21:37 浏览:716
苹果手机如何迁移软件到安卓手机 发布:2024-09-20 17:21:34 浏览:692
查看服务器ip限制 发布:2024-09-20 16:56:27 浏览:389
p搜系统只缓存1页为什么 发布:2024-09-20 16:48:51 浏览:841
上网的账号和密码是什么东西 发布:2024-09-20 16:31:31 浏览:613
安卓手机王者荣耀如何调超高视距 发布:2024-09-20 16:31:30 浏览:429